| Column | Field | Description | SQL Type | Length | Decimals | SAP Type | Default Value | Null Allowed | CheckTable | Rollname | SQL Create Statement |
---|
| 1 | MANDT | Client | nvarchar | 3 | 0 | CLNT | (N'000') | No | T000 | MANDT | Allow NULL? |
| 2 | BUKRS | Company Code | nvarchar | 4 | 0 | CHAR | (N' ') | No | T001 | BUKRS | Allow NULL? |
| 3 | SPARTE | Division | nvarchar | 2 | 0 | CHAR | (N' ') | No | TSPA | SPARTE | Allow NULL? |
| 4 | PROTMS | Log automatic estimation | char | 1 | 0 | CHAR | (N' ') | Yes | | PROTMS | Allow NULL? |
| 5 | EABLAEND | Meter reading results can be changed | char | 1 | 0 | CHAR | (N' ') | Yes | | EABLAEND | Allow NULL? |
| 6 | EABLBELG | Indicator: do not print meter reading document in spool | char | 1 | 0 | CHAR | (N' ') | Yes | | EABLBELG | Allow NULL? |
| 7 | E_ZUKERF | Limitation on MR date of MR result | char | 1 | 0 | CHAR | (N' ') | Yes | | E_ZUKERF | Allow NULL? |
| 8 | UEFAKTOR1 | Overestimation factor in percent | decimal | 3 | 1 | DEC | ((0)) | Yes | | UEFAKTOR1 | |
| 9 | UEFAKTOR2 | Overestimation factor in percent | decimal | 3 | 1 | DEC | ((0)) | Yes | | UEFAKTOR2 | |
| 10 | KARSCHLABL | Interval for suppression of meter readings for final MR | nvarchar | 3 | 0 | NUMC | (N'000') | Yes | | KARSCHLABL | Allow NULL? |
| 11 | KON_REL | Auto. reflect device replacement in meter reading results | char | 1 | 0 | CHAR | (N' ') | Yes | | DEVREPLACE | Allow NULL? |
| 12 | DUMMYES | Create dummy EABL for meter reading order creation | char | 1 | 0 | CHAR | (N' ') | Yes | | DUMMYES | Allow NULL? |
| 13 | MSPRUMZ | No automatic disconnection for move-in/out | char | 1 | 0 | CHAR | (N' ') | Yes | | MSPRUMZ | Allow NULL? |
| 14 | LEISTMS | Estimation of watt and resetting registers | char | 1 | 0 | CHAR | (N' ') | Yes | | LEISTMS | Allow NULL? |
| 15 | KOABLVOR | Prepare control reading | char | 1 | 0 | CHAR | (N' ') | Yes | | KOABLVOR | Allow NULL? |
| 16 | PRORUECK | Resetting for control/interim meter reading | char | 1 | 0 | CHAR | (N' ') | Yes | | PRORUECK | Allow NULL? |
| 17 | SERVICEABW | Create service notification or order | char | 1 | 0 | CHAR | (N' ') | Yes | | SERVICEABW | Allow NULL? |
| 18 | IGNESTIRESULTS | Ignore Estimated Meter Reading Results During Extrapolation | char | 1 | 0 | CHAR | (N' ') | Yes | | IGNESTIRESULTS | Allow NULL? |
| 19 | INTERVUPLPER | MROC interval for upload of periodic results | nvarchar | 3 | 0 | NUMC | (N'000') | Yes | | INTERVUPLPER | Allow NULL? |
| 20 | INTFROMESTIRES | Also Derive from Estimated MR Results | char | 1 | 0 | CHAR | (N' ') | Yes | | INTFROMESTIRES | Allow NULL? |
| 21 | KAUFERSTRUHANL | No meter reading order creation for inactive installations | char | 1 | 0 | CHAR | (N' ') | Yes | | KAUFERSTRUHANL | Allow NULL? |
| 22 | PROPOSE_MOVEIN | Display default move-in value | char | 1 | 0 | CHAR | (N' ') | Yes | | PROPOSE_MOVEIN | Allow NULL? |
| 23 | INTV_PROP_MOVEIN | Interval for determining default value for move-in | nvarchar | 3 | 0 | NUMC | (N'000') | Yes | | INTV_PROP_MOVEIN | Allow NULL? |
| 24 | INTV_INTERNET | Interval for internet meter reading | nvarchar | 3 | 0 | NUMC | (N'000') | Yes | | INTV_INTERNET | Allow NULL? |
| 25 | TREAT_INTERNETMR | Upload from Internet Meter Reading | char | 1 | 0 | CHAR | (N' ') | Yes | | TREAT_INTERNETMR | Allow NULL? |
| 26 | NOCHGE_BACKBMRES | No change to billed reading during floating backbilling | char | 1 | 0 | CHAR | (N' ') | Yes | | CHGE_BACKB_MRRES | Allow NULL? |
| 27 | NOCHGE_DPCMRES | No Change to Billed Meter Reading for Dynamic Period Control | char | 1 | 0 | CHAR | (N' ') | Yes | | CHGE_DPC_MRRES | Allow NULL? |
| 28 | INTV_DEVREPL | Device replacement interval | nvarchar | 3 | 0 | NUMC | (N'000') | Yes | | INTV_DEVREPL | Allow NULL? |
| 29 | DEVREPL_DIALOG | Device Replacement (Dialog) Automatically Taken into Account | char | 1 | 0 | CHAR | (N' ') | Yes | | DEVREPLACE_DIALOG | Allow NULL? |
| 30 | INTV_INTERIM | Interval for Interim Meter Reading | nvarchar | 3 | 0 | NUMC | (N'000') | Yes | | INTV_INTERIM | Allow NULL? |
| 31 | TREAT_INTERIMMR | Handling of Interim Meter Reading with Billing During Upload | char | 1 | 0 | CHAR | (N' ') | Yes | | TREAT_INTERIMMR | Allow NULL? |
| 32 | AMI_DER_INTERVAL | Interval for Derivation During AMI Entry | nvarchar | 3 | 0 | NUMC | (N'000') | Yes | | E_AMI_MR_DERINTERVAL | Allow NULL? |
| 33 | QDPLCHECK | Validation for Final Quantity | char | 1 | 0 | CHAR | (N' ') | Yes | | E_QDPLCHECK | Allow NULL? |