SAP TABLES

SAP Tables - SAP Business One/ERP Table Definition reference

sap.erpref.com

Schema:
 Module:  Table: 
Column: 
Searchbeta 

icon of database logic symbol SAP  TABLESv1Made in Britain

JDETables.com - the webs number one JD Edwards Table Definition reference

ERP 6.0: Top 10 requests

TableColumnsDescription
1TJKWE15IS-M/SD: WBZ, Order Data for Inbound Processing
2RSADMINC96Customizing Table General BW
3BBP_PD_XML8Table for Persistent Class CL_XML_PPF_BBP
4/OTX/RM_TELIB24Enterprise Library Server Settings
5UMV_TR1259Obsolete:Val.Driver Tree:Assign.Web Reports to Value Drivers
6FIQAC_PART8Reporting Parameters Text for Company Code ( Qatar)
7/ISDFPS/CHVW_E34External Batch Where-Used List
8/1RA/0SD010MI170Items for Class SD01 - Raw Data
9FMARCPAR4Parallelization of FMARC_BATCH
10CEKRS5Movement type parameters for automatic ERS

B1 9.2: Top 10 requests

TableColumnsDescription
1OITM299Items
2OINV386A/R Invoice
3OCRD332Business Partner
4ORDR386Sales Order
5INV1265A/R Invoice - Rows
6OJDT100Journal Entry
7OPCH386A/P Invoice
8OVTG52Tax Definition
9OPOR386Purchase Order
10JDT1124Journal Entry - Rows

B1 8.8: Top 10 requests

TableColumnsDescription
1OITM249Items
2ORCT154Incoming Payment
3OINV268A/R Invoice
4OVPM154Outgoing Payments
5OIVL77Whse Journal
6OPCH268A/P Invoice
7JDT1110Journal Entry - Rows
8OOCR9Loading Factors
9OSRN20Serial Numbers Master Data
10OBOT10Bill Of Exchang Transaction
Industry Specific :: SAP Utilities :: Device Management :: Meter Reading
ProductVersionTableColumnsIndexesDescriptionModule
1ERP EHP76.0TE410S221Performance Parameters for Meter Reading Data EntryMeter Reading
SQL:  selectupdate insert create

Use the column checkboxes to build your query. Header columns sets/unsets all columns

SELECT MANDT, OUTPUTTOGETHER, OPENTOGETHER, REGNUMBERINST, EABL_CONS_CHECK, NO_EABL_AUTH_CHK, EL29_ONLY_PLAUS, EL27_NO_GRP_PREM, NO_DEPVAL_SECREG, RATETYPE_MRREL, ASSESS_CONTROLMR, NO_INSTAL_PROPSL, NO_ENT_MRREAS_08, DIFF_MRUS_EL35, REESTIM_MR, EG42_ADAPT_FMR, TURBOUPLOAD, EL31_COUNT_BLOCK, EL31_DEFAULT_LAY, EL348_FOLLOWUP, ELHR_BEFORE_MRR2, ELHR_PREV_INVALI FROM TE410S
ColumnFieldDescriptionSQL TypeLengthDecimalsSAP TypeDefault ValueNull AllowedCheckTableRollnameSQL Create Statement
1MANDTClientnvarchar30CLNT(N'000')No*MANDT Allow NULL? 
2OUTPUTTOGETHERNumber of meter reading orders to be output togetherdecimal120DEC((0))NoOUTPUT_TOGETHER
3OPENTOGETHERNumber of objects processed togetherdecimal120DEC((0))NoOPEN_TOGETHER
4REGNUMBERINSTNumber of Registersdecimal120DEC((0))NoREGNUMBER_INST
5EABL_CONS_CHECKActivate Consistency Check for Table of Meter Reading Docs.char10CHAR(N' ')YesEABL_CONS_CHECK Allow NULL? 
6NO_EABL_AUTH_CHKNo authorization check for meter reading documents tablechar10CHAR(N' ')YesNO_EABL_AUTH_CHK Allow NULL? 
7EL29_ONLY_PLAUSDisplay plausible meter readings onlychar10CHAR(N' ')YesEL29_ONLY_PLAUS Allow NULL? 
8EL27_NO_GRP_PREMDisplay implausible meter readings onlychar10CHAR(N' ')YesEL27_NO_GRP_PREMSE Allow NULL? 
9NO_DEPVAL_SECREGDo not include secondary meter in dependent validationchar10CHAR(N' ')YesDO_DEPCAL_SECREG Allow NULL? 
10RATETYPE_MRRELChanges to Rate Type Relevant to Meter Readingchar10CHAR(N' ')YesRATETYPE_MRREL Allow NULL? 
11ASSESS_CONTROLMRAssessing also for MR Reasons Not Triggerd by Billng (09,10)char10CHAR(N' ')YesASSESS_CONTROLMR Allow NULL? 
12NO_INSTAL_PROPSLPropose Meter Readings at Installationchar10CHAR(N' ')YesINSTALL_PROPOSAL Allow NULL? 
13NO_ENT_MRREAS_08No Entry of Tech. MRs at Installation Outside Installationchar10CHAR(N' ')YesNO_ENT_MRREAS_08 Allow NULL? 
14DIFF_MRUS_EL35Different Meter Reading Units for Serial Switchingchar10CHAR(N' ')YesDIFF_MRUS_EL35 Allow NULL? 
15REESTIM_MRReestimation of Meter Reading Resultschar10CHAR(N' ')YesREESTIM_MR Allow NULL? 
16EG42_ADAPT_FMRMeter Reading Orders/Results in EG42char10CHAR(N' ')YesEG42_ADAPT_FMR Allow NULL? 
17TURBOUPLOADActivates Accelerated Processingchar10CHAR(N' ')YesE_BOOSTER Allow NULL? 
18EL31_COUNT_BLOCKCount Installations with Billing Lockchar10CHAR(N' ')YesEL31_COUNT_BLOCKED Allow NULL? 
19EL31_DEFAULT_LAYAutomatically Use Default Layout for ALVchar10CHAR(N' ')YesEL31_DEFAULT_LAYOUT Allow NULL? 
20EL348_FOLLOWUPSet Meter Reading Status to Implausible According to EL 348char10CHAR(N' ')YesEL348_FOLLOWUP Allow NULL? 
21ELHR_BEFORE_MRR2Use Entire Meter Reading History for Exrapolationchar10CHAR(N' ')YesELHR_BEFORE_MRR21 Allow NULL? 
22ELHR_PREV_INVALIExtrapolation Ignores Implausible Meter Reading Resultschar10CHAR(N' ')YesELHR_PREV_INVALID Allow NULL? 
NamePrimaryUniqueTypeColumns
TE410S~0YesYesCLUSTEREDMANDT